AAMI ID26 pdf free download.Medical electrical equipment—Part 2: Particular requirements for the safety of infusion pumps and controllers.
“Amendment” means that the clause or subclause of the General Standard is amended as indicated by the text of this Particular Standard. Subclauses or figures which are additional to those of the General Standard are numbered starting from 101, additional annexes are lettered AA, BB, etc., and additional items aa), bb), etc. The term “this Standard” is used to make reference to the General Standard, the Collateral Standard, and this Particular Standard taken together. Where there is no corresponding section, clause, or subclause in this Particular Standard, the section, clause, or subclause of the General Standard, although possibly not relevant, applies without modification; where it is intended that any part of the General Standard, although possibly relevant, is not to be applied, a statement to that effect is given in this Particular Standard. The requirements of this Particular Standard take priority over those of the General Standard. The requirements are followed by specifications for the relevant tests. Following the decision taken by subcommittee 62D at the meeting in Washington in 1979, a “General guidance and rationale” section giving some explanatory notes, where appropriate, about the more important requirements is included in Annex AA. Clauses or subclauses for which there are explanatory notes in Annex AA are marked with an asterisk (*). It is considered that a knowledge of the reasons for these requirements will not only facilitate the proper application of the standard but will, in due course, expedite any revision necessitated by changes in clinical practice or as a result of developments in technology. However, this annex does not form part of the requirements of this Standard.2.102 VOLUMETRIC INFUSION PUMP INFUSION PUMP in which the delivery rate is set by the OPERATOR and indicated by the EQUIPMENT in volume per unit of time, but excluding SYRINGE PUMPS 2.103 DRIP – RATE INFUSION PUMP INFUSION PUMP in which the delivery rate is set by the OPERATOR and indicated by the EQUIPMENT as a number of drops per unit of time 2.104 INFUSION CONTROLLER EQUIPMENT intended to regulate the flow of liquid into the PATIENT under positive pressure generated by gravitational force 2.105 VOLUMETRIC INFUSION CONTROLLER INFUSION CONTROLLER in which the delivery rate is set by the OPERATOR and indicated by the EQUIPMENT in volume per unit of time 2.106 DRIP – RATE INFUSION CONTROLLER INFUSION CONTROLLER in which the delivery rate is set by the OPERATOR and indicated by the EQUIPMENT as a number of drops per unit of time 2.107 SPECIAL USE EQUIPMENT EQUIPMENT in which the delivery rate is set by the OPERATOR and indicated by the EQUIPMENT in units other than those defined in 2.101 to 2.106 2.108 SYRINGE PUMP EQUIPMENT intended for controlled infusion of liquids into the PATIENT by means of one or more single action syringe(s) or similar container(s) (e.g., where the cartridge is emptied by pushing on its plunger) and in which the delivery rate is set by the OPERATOR and indicated by the EQUIPMENT in volume per unit of time 2.109 INFUSION PUMP FOR AMBULATORY USE EQUIPMENT intended for the controlled infusion of liquids into the PATIENT and intended to be carried continuously by the PATIENT.AAMI ID26 pdf download.

Other IEC Standards

Categories